Henny Penny Model OE-100
SECTION 2. MAINTENANCE
2-1. INTRODUCTION
This section provides procedures for checking and replacement of the
various parts used within the unit. Before replacing any parts, refer to
Section 1, Troubleshooting. It will aid you in determining the cause of a
particular malfunction.
2-2. TEST INSTRUMENTS
You may use two test instruments to check the electric compo-
nents.
A continuity light.
An ohmmeter.
When the manual refers to the circuit being closed, the continuity
light will be illuminated or the ohmmeter should read zero (0)
unless otherwise noted.
When the manual refers to the circuit being open, the continuity
light will not illuminate or the ohmmeter will read one (1).
NOTE
A continuity light cannot be used to check coils or motors.
2-3. REMOVING THE
CONTROL PANEL
To replace parts located inside the fryer, you will need to remove the
control panel. The following steps provide the correct procedure.
1. Place the power switch in the OFF position.
Disconnect the power cord from the wall receptacle or
power at the fuse or breaker box, or electrical shock could
result.
2. Remove the decorative strip, one located on each side of the
control panel, by removing the screw located on the bottom
of the decorative strip.
593
Seitenansicht 0
1 2 3 4 5 6 ... 21 22

Inhaltsverzeichnis

Seite 1 - SECTION 2. MAINTENANCE

2-1Henny Penny Model OE-100SECTION 2. MAINTENANCE2-1. INTRODUCTION This section provides procedures for checking and replacement of thevarious parts u

Seite 2

Henny Penny Model OE-1002-102-10. FUSESTo avoid electrical shock or other injury, before startingthis procedure, move power switch to the OFF position

Seite 3

2-11Henny Penny Model OE-1002-12. FILTER HEATERSWITCHCheckoutThe Filter Heater Switch is a rocker type switch. With the switchin the "ON" po

Seite 4

Henny Penny Model OE-1002-122-13. FILTER HEATER593This unit is equipped with a strip heater in the event solidified shorten-ing accumulates in the fil

Seite 5

2-13Henny Penny Model OE-1002-14. FILTERING SYSTEM The filtering system consists of the filter valve, motor and filter pumpassembly, filter screen ass

Seite 6

Henny Penny Model OE-1002-142-15. FILTER VALVE The filter valve is a 3/8 inch two-way stainless steel ball valve. If thisvalve should develop leaks th

Seite 7

2-15Henny Penny Model OE-1002-16. FILTER PUMPREPAIR (Continued)3. To reassemble, place rotor on drive shaft, and place rollers intorotor.NOTEA small a

Seite 8

Henny Penny Model OE-1002-162-18. PUMP AND MOTORREPLACEMENT1. To replace the pump and motor assembly, insure the main powerhas been removed from the f

Seite 9

2-17Henny Penny Model OE-1002-19. COOLING FANMAINTENANCE(Continued)5. Close door and turn power switch on. Unit is now ready foroperation.If the fan n

Seite 10 - Henny Penny Model OE-100

Henny Penny Model OE-1002-18994

Seite 11

2-19Henny Penny Model OE-1001197

Seite 12

Henny Penny Model OE-1002-22-4. THERMAL SENSOR The thermal sensor determines the shortening temperature. If a mal-function does occur, an E6 will be d

Seite 13

Henny Penny Model OE-1002-201197

Seite 14

2-21Henny Penny Model OE-100694

Seite 15

Henny Penny Model OE-1002-221294

Seite 16

2-3Henny Penny Model OE-1002-5. HIGH TEMPERATURELIMIT CONTROLThe high temperature limit control is a manual reset control whichsenses the temperature

Seite 17

2-4Model OE-1004092-5. HIGH TEMPERATURELIMIT CONTROL(Continued)Before following these steps, place POWER switch in theOFF position and unplug the powe

Seite 18

2-5Henny Penny Model OE-1002-6. HEATING ELEMENTSNOTEHeating elements are available for 208 and 480 voltage.Check the data plate to determine the corre

Seite 19

Henny Penny Model OE-1002-62-6. HEATING ELEMENTS(Continued)1091Replacement1. Drain the shortening from the frypot.2. Remove the heating element wire f

Seite 20

2-7Henny Penny Model OE-1002-7. CONTACTORSThe following checks are performed with the wall circuitbreaker closed and the Power switch in the ON positi

Seite 21

Henny Penny Model OE-1002-82-8. FAN The Henny Penny OE-100 has a fan in the circuit which operates onlywhen the power switch is in the COOK position.

Seite 22

2-9Henny Penny Model OE-1002-8. FAN (Continued) 2. Label and disconnect fan motor wires.3. Remove the four screws, washers, and nuts securing the fan