Model 590/592This section provides checkout and replacement procedures, for various parts of the fryer. Before replacing any parts, refer to the
Model 590/592The pressure pads are plastic strips that the lid cam presses against to seal the lid.1. Raise the lid.2. Remove the 4 screws securing
Model 590/592If steam leaks out from around the lid gasket, the pressure pads could be worn or broken. If the pressure pad is worn, but not broken, i
Model 590/592This is an electro-mechanical device that causes pressure to be held in the frypot. The solenoid valve closes at the beginning of the Coo
Model 590/592 5. If the core-disc assembly is sticking due to buildup of shortening, breading, and food particles, proceed with the
Model 590/592 13. Wet “O” ring around seat with water and insert O-ring assembly (fl at side fi rst) in valve through “IN” side of body.
Model 590/592 DO NOT PULL THE RING ON THE SAFETY RELIEF VALVE. HOT STEAM WILL BE RELEASED AND SEVERE BURNS WILL RESULT.
Model 590/592 2. Use a wrench to loosen the valve from the pipe tee, turn counterclockwise to remove. 3. Clean the inside of the p
Model 590/592 The electric fryer requires two switching contactors: a primary and a heat contactor. The primary contactor energizes (contacts close)
Model 590/592 To avoid electrical shock, make connections before applying power, take reading, and remove power before removing meter leads
Model 590/592 The electric model fryer uses 2 heating elements. Heating elements are available in 208, 220/240, 380 and 415 volts. Check the d
Model 590/592This high temperature control is a safety, manual reset control, which senses the temperature of the shortening. If the shorten-ing tem
Model 590/592 Replacement 1. Drain the shortening. 2. Remove the high limit bulb holder from the heating element inside the frypot. 3. Disconnec
Model 590/59210. Replace the brass nuts and washers on the heating element terminals. Tighten the brass nuts to 30 foot lbs of torque.11. Replac
Model 590/592 Upon pulling out on the drain handle, the microswitch should be activated and the unit will not heat, but when the handle is pushed
Model 590/592 The drain valve opens when the drain valve handle is pulled out and drains the shortening out of the pot.Replacement 1. Using a 3/8” so
Model 590/592 1. Raise the lid and remove the retention ring from one end of the lid pin. 2. Slide the lid pin from unit. 3. Lift the lid fr
Model 590/5921103 2-252-23. NYLATRON STRIPS REPLACEMENT (Continued 9. Lift the front shroud up and out, over
Model 590/592 To avoid electrical shock of property damage, move the power switch to OFF and disconnect main circuit breaker, or unplug cord
Model 590/59211. Pull excess capillary line from pot and tighten nut into frypot wall. Be sure capillary bulb of high limit is position
Model 590/592The POWER/PUMP switch is a three way rocker switch with a center OFF position. With switch in the POWER position, the fryer operates. Wit
Model 590/592The temperature probe relays actual shortening temperature to the control. If it becomes disabled, “E06” will show in the dis-play. Also,
Model 590/592Should the control panel become inoperative, follow these instructions for replacing the board.1. Remove electrical power supplied to t
Model 590/592The Lid Assembly is easily tilted up for cleaning or servicing. 1. Raise the lid and remove racks and carrier.2. Grasping t
Model 590/592The Lid Counterweight in the back of the fryer balances the weight of the lid system to allow easier opening and closing of the lid. The