Model 691
2-8. GAS PRESSURE The gas pressure regulator on the gas control valve is
REGULATOR SETTING factory set as follows:
Natural: 3.5 inches water column (0.87 kPa)
Propane: 10.0 inches water column (2.49 kPa)
MAKE SURE GAS PRESSURE IS SET COR-
RECTLY. FAILURE TO DO SO CAN RESULT IN
SHORTENING OVERFLOWING THE FRYPOT,
WHICH COULD CAUSE SERIOUS BURNS,
PERSONAL INJURY, FIRE, AND/OR PROPERTY
DAMAGE.
2-9. ELECTRICAL The gas fryer requires 120 volt, 60 Hertz, 1 phase, 10 amp,
REQUIREMENTS 3-wire grounded (earthed) service, or 230 volt, 50 Hertz, 1 phase,
5 amp service. The 120-volt gas fryer is factory equipped with a
grounded (earthed) cord and plug for your protection against
shock, and should be plugged into a three-prong grounded
(earthed) receptacle. Do not cut or remove grounding (earthing)
prong. A wiring diagram is located behind the right side panel and
can be accessed by removing the side panel. The 230 volt plug
must conform to all local, state, and national codes.
Do not disconnect the ground plug. This fryer must be
adequately and safely grounded or electrical shock
could result. Refer to local electrical codes for correct
grounding procedures or in absence of local codes, with
The National Electrical Code, ANSI/NFPA No. 70 (the
current edition). In Canada, all electrical connections
are to be made in accordance with CSA C22.1,
Canadian Electrical Code Part 1, and/or local codes.
To avoid electrical shock, this appliance must be
equipped with an external circuit breaker which will
disconnect all ungrounded (unearthed) conductors. The
main power switch on this appliance does not disconnect
all line conductors.
803 2-9